← 論文一覧に戻る

CO2地中貯留における長期環境リスク・モニタリングギャップ・世代間責任:批判的レビューと概念的枠組み

Long-term environmental risks, monitoring gaps, and intergenerational responsibility in CO2 geological storage: a critical review and conceptual framework (原題)

Tianbiao Zhao, Hu Li

Frontiers in Earth Science📚 査読済 / ジャーナル2026-11-17#CCUSOrigin: CN対象セクター: power
DOI: 10.3389/feart.2026.1992886
原典: https://doi.org/10.3389/feart.2026.1992886

🤖 gxceed AI 要約

日本語

CCUSの気候価値はCO2の永続的貯留という前提に依存するが、その根拠は数十年の観測に過ぎず、貯留責任は数百年〜数千年に及ぶ。本論文は長期環境リスク・モニタリング・法的責任の三側面を批判的に統合し、米EUの20〜50年の操業者責任がリスク期間と不整合であること、中国には長期責任法制が未整備であることを指摘する。核廃棄物分野の千年スケール先例を援用し、技術的検証可能性・制度的継続性・認識的謙虚さの三本柱からなる世代間環境責任の概念的枠組みを提案する。

English

CCUS's climate value rests on permanent CO2 storage, yet evidence spans decades while the storage commitment extends centuries to millennia. This review synthesizes long-term environmental risks, monitoring limitations, and liability gaps, noting that US and EU operator obligations of 20–50 years mismatch the risk horizon and China lacks dedicated long-term liability law. Drawing on nuclear-waste precedents (Yucca Mountain, OECD/NEA RK&M), it proposes an intergenerational responsibility framework built on technical verifiability, institutional continuity, and epistemic humility.

Unofficial AI-generated summary based on the public title and abstract. Not an official translation.

📝 gxceed 編集解説 — Why this matters

日本のGX文脈において

日本はCCUS/貯留の法制度整備が途上にあり、事業者責任の期間設計やモニタリング体制を検討する際の参照枠組みとして有用。GX推進法・CCS事業化検討に制度的示唆を与える。

In the global GX context

Speaks directly to the global gap between CCUS deployment incentives and long-term liability/monitoring design under emerging frameworks; relevant to ISSB/TCFD-adjacent disclosure of deferred environmental risk and to transition-finance due diligence on CCUS assets.

👥 読者別の含意

🔬研究者:CCUSの長期リスク・責任配分・モニタリング手法の研究課題を整理する枠組みとして活用できる。

🏢実務担当者:CCS事業の長期責任・モニタリングコスト・制度設計リスクを投資判断や開示で考慮する際の論点を提供する。

🏛政策担当者:CCS大規模展開前に長期責任法制とモニタリング体制を先行整備すべき根拠として参照できる。

📄 Abstract(原文)

The climate value of Carbon Capture, Utilization and Storage (CCUS) hinges on the assumption that CO 2 can be stored permanently. Yet this assumption rests on evidence gathered over decades, while the storage commitment extends across centuries to millennia. This paper critically synthesizes available evidence across three dimensions. For long-term environmental risks, the four trapping mechanisms operate on different timescales, and the uncertainties associated with leakage pathways through abandoned wells, caprock heterogeneity, and injection-induced geomechanical responses cannot be fully resolved by short-term monitoring records. For monitoring, existing technologies involve trade-offs among sensitivity, spatial coverage, duration, and cost, with no viable solutions for centennial-scale stewardship, and the attribution of anomalous signals remains methodologically underdeveloped. For liability, the United States and the European Union limit operator obligations to 20–50 years, creating a temporal mismatch with the risk horizon, while China has yet to enact dedicated legislation for long-term liability. Drawing on millennial-scale precedents from the nuclear industry, specifically the Yucca Mountain disposal standards and the OECD/NEA Records, Knowledge and Memory (RK&M) project, this paper proposes a conceptual framework for intergenerational environmental responsibility based on three pillars: technical verifiability, institutional continuity, and epistemic humility. Given the structural feature of CCUS in which benefits accrue now while risks are deferred, institutional design needs to be in place before large-scale deployment locks in irreversible commitments.