再生可能エネルギー基盤スマート電力システム:協調制御と性能評価
Renewable Energy-Based Smart Power Systems: Coordinated Control and Performance Assessment (原題)
Al-Araji, Adil Hamzah Ahmed
🤖 gxceed AI 要約
日本語
太陽光・風力・蓄電池・インバータ無効電力支援・OLTC制御を統合した協調制御フレームワークをIEEE33バス配電網で評価。系統輸入電力量27.58%減、損失60.47%減、最低電圧0.9626p.u.へ改善、運用コスト約27%減、炭素排出27.58%減、周波数ナディアも改善した。再エネ大量導入下の配電網運用に技術・経済・環境の三面で有効性を示す。
English
An integrated framework combining PV, wind, battery storage, inverter reactive power support and OLTC control is evaluated on the IEEE 33-bus network across three scenarios. Coordinated operation cuts daily grid imports 27.58%, feeder losses 60.47%, operating costs ~27% and carbon emissions 27.58%, while raising minimum voltage to 0.9626 p.u. and improving frequency nadir. It demonstrates technical, economic and environmental gains for renewable-rich distribution networks.
Unofficial AI-generated summary based on the public title and abstract. Not an official translation.
📝 gxceed 編集解説 — Why this matters
日本のGX文脈において
日本では再エネ大量導入に伴う配電網の電圧・周波数課題が顕在化しており、蓄電池と配電制御の協調は電力会社の系統運用・GX投資判断に示唆を与える。ただしSSBJ・開示制度との直接接続はない。
In the global GX context
Grid integration and voltage/frequency management for high-renewable distribution networks is a shared challenge across ISSB-reporting utilities and transition-finance-backed grid investment; the quantified loss and emission reductions offer a replicable assessment template.
👥 読者別の含意
🔬研究者:再エネ・蓄電池・OLTC協調制御の定量評価手法と標準モデルでの比較設計を参考にできる。
🏢実務担当者:配電系統運用や再エネ調達・蓄電池投資の効果試算に、損失・コスト・排出削減の定量指標を活用できる。
🏛政策担当者:再エネ大量導入時の系統増強・蓄電池導入政策の費用対効果を検討する際の評価枠組みとして参照可能。
📄 Abstract(原文)
The increasing integration of renewable energy sources into distribution networks requires coordinated control and energy management strategies to ensure reliable, efficient, and cost-effective operation. This study presents an integrated framework combining solar photovoltaic and wind generation, battery energy storage (BES), inverter-based reactive power support, and coordinated on-load tap-changer (OLTC) control. The IEEE 33-bus radial distribution network, with a total demand of 3.715 MW and 2.300 MVAr, is used to evaluate three operating scenarios: conventional grid-based operation, renewable energy integration without coordinated control, and coordinated operation using the proposed framework. A 24-hour simulation framework incorporates renewable generation and demand profiles, battery scheduling, backward/forward-sweep AC power flow, voltage assessment, operating cost evaluation, grid-related carbon emissions estimation, and dynamic frequency response analysis. The results demonstrate improvements in network performance under coordinated operation. Daily grid energy imports decrease from 70.206 to 50.843 MWh, a reduction of 27.58%, while peak grid import decreases from 3.926 to 2.895 MW. Daily feeder energy losses decline from 2.928 to 1.157 MWh, representing a 60.47% reduction. The minimum bus voltage increases from 0.9038 to 0.9626 p.u., eliminating hourly voltage violations below 0.95 p.u. Daily operating costs decrease by approximately 27.01%, while grid-related carbon emissions decline by 27.58%, based on the assumed emission factor. Furthermore, the frequency nadir improves from 49.732 to 49.910 Hz, and the peak rate of change of frequency decreases from 0.569 to 0.112 Hz/s. These findings highlight the potential of coordinated renewable generation, battery storage, inverter-based reactive power support, and OLTC control to enhance voltage regulation, reduce energy losses, and improve the technical, economic, and environmental performance of renewable-rich distribution networks.
🔗 Provenance — このレコードを発見したソース
- Zenodo https://zenodo.org/records/23683836first seen 2026-10-28 04:14:59
🔔 こうした論文の新着を逃したくない方は キーワードアラート に登録(無料・3キーワードまで)。
gxceed は公開メタデータに基づく研究支援データセットです。要約・翻訳・解説は AI 支援で生成されています。 最終的な解釈・検証は利用者が原典資料に基づいて行うことを前提とします。