非連系島における電力・フェリー脱炭素化のための再エネ・水素セクターカップリング:ギリシャ・ガヴドス島の実現可能性評価
Renewable-Hydrogen Sector Coupling for Electricity and Ferry Decarbonization on a Non-Interconnected Island: A Feasibility Assessment of Gavdos, Greece (原題)
Panagiotis Pasinios, Alexandros Kelmalis, Andreas Dimou, Stergios Vakalis
🤖 gxceed AI 要約
日本語
ギリシャの非連系島ガヴドスを対象に、PV340kWp・風力800kW・余剰電力水素製造の構成を評価した。年間電力需要の98.19%を再エネで賄い、電解装置は年間34.488tの水素を製造、フェリー需要33.890tを上回る。日次では130日で生産が需要を下回るが、蓄積水素により在庫は非負を維持し、季節変動対応に約1.1tの水素貯蔵が必要と示した。
English
A feasibility assessment of a PV (340 kWp), wind (800 kW), and surplus-fed electrolysis configuration for Gavdos, a non-interconnected Greek island. Renewables cover 98.19% of annual electricity demand, and the 302.6 kW electrolyzer produces 34.488 t H2/yr gross versus 33.890 t ferry demand. Although daily output falls short on 130 days, accumulated hydrogen keeps inventory non-negative, requiring ~1,133 kg usable storage including a two-day reserve.
Unofficial AI-generated summary based on the public title and abstract. Not an official translation.
📝 gxceed 編集解説 — Why this matters
日本のGX文脈において
島嶼部の再エネ・水素セクターカップリングは、日本の離島(奄美・沖縄・五島列島等)における脱炭素モデルと親和性が高く、地域エネルギー計画や水素社会実装の参考になる。
In the global GX context
Adds island-level empirical evidence to the global hydrogen and sector-coupling literature, relevant to non-interconnected grid decarbonization and maritime fuel transition debates beyond mainland-centric studies.
👥 読者別の含意
🔬研究者:非連系系統における再エネ・水素カップリングの需給バランス評価手法(月別代表プロファイルと時系列ディスパッチの対応)の実例として参考になる。
🏢実務担当者:離島での再エネ余剰電力を使った水素製造・貯蔵の規模感と季節変動対応の必要性を把握できる。
🏛政策担当者:離島の電力・交通脱炭素政策において、再エネ導入と水素貯蔵容量の設計指針を得る材料になる。
📄 Abstract(原文)
Gavdos is assessed as a non-interconnected island without mainland electricity exchange over the adopted planning horizon. A configuration with 340 kWp of photovoltaics, an 800 kW wind turbine, and surplus-fed electrolysis is evaluated for electricity supply and ferry hydrogen. Twelve public HEDNO monthly day-ahead files were concatenated into an 8760 h rolling-year demand series. RETScreen-based F-chart solar calculations and a Weibull wind distribution (k = 2) provided twelve representative monthly 24 h renewable profiles, mapped by month and hour to the dispatch chronology. Renewable generation first serves demand; deficits are assigned to conventional generation and surplus to electrolysis. Annual demand is 662.630 MWh, of which renewables supply 650.633 MWh directly (98.19%); the residual deficit is 11.997 MWh across 419 h. The 302.6 kW baseline electrolyzer produces 34.488 t H2 year−1 gross versus a ferry demand of 33.890 t H2 year−1. Although daily production is lower than demand in 130 days, accumulated hydrogen keeps the gross inventory non-negative. The maximum seasonal drawdown is 947.4 kg, giving a usable hydrogen-mass requirement of 1133.1 kg including a two-day reserve. The results demonstrate gross-production compatibility under the adopted assumptions; net ferry-fuel adequacy requires detailed assessment of component operation, auxiliary loads, storage, delivery, and vessel duty.
🔗 Provenance — このレコードを発見したソース
- crossref https://doi.org/10.3390/electricity7040133first seen 2026-11-13 06:24:49
🔔 こうした論文の新着を逃したくない方は キーワードアラート に登録(無料・3キーワードまで)。
gxceed は公開メタデータに基づく研究支援データセットです。要約・翻訳・解説は AI 支援で生成されています。 最終的な解釈・検証は利用者が原典資料に基づいて行うことを前提とします。