低炭素建築向け住宅用太陽光発電システムの設計
Design of Residential Photovoltaic Power Generation Systems for Low-Carbon Buildings (原題)
Chenxi Zhang
🤖 gxceed AI 要約
日本語
上海の戸建住宅を対象に、低炭素化のための系統連系太陽光発電システムの電気設計を提示した研究。冬季需要17.8kWh/日等の条件からPV容量8.43kWを算出し、10.08kWp・24枚の単結晶モジュール構成を選定。DC400Vバス、昇圧コンバータ10kHz、SPWMインバータ20kHz、LCLフィルタを規定し、電圧一定+P&O方式のハイブリッドMPPTで日射変動時の追従性を確認、系統電流の高調波歪みは2.45%と設計上限5%を下回った。
English
This study presents an electrical design of a grid-connected rooftop PV system for a low-carbon detached house in Shanghai. From a winter demand of 17.8 kWh/day, 3.8 h/day sunshine and a 1.8 loss coefficient, PV capacity is sized at 8.43 kW, selecting a 10.08 kWp array of 24 mono-crystalline modules (48.0 m2). The design specifies a 400 V DC bus, 10 kHz boost converter, 20 kHz SPWM inverter and LCL grid filter, with a hybrid constant-voltage/perturb-and-observe MPPT that tracks the new MPP after an irradiance drop; grid current THD is 2.45%, below the 5% limit.
Unofficial AI-generated summary based on the public title and abstract. Not an official translation.
📝 gxceed 編集解説 — Why this matters
日本のGX文脈において
日本のGX文脈では、住宅用PVの系統連系設計や需給バランスはZEH普及・再エネ大量導入下の配電網制約と直結する。技術設計の実務的知見として、住宅脱炭素や系統安定化を担う事業者・自治体に参考となる。
In the global GX context
Globally, residential rooftop PV design and grid-interface engineering feed into building decarbonisation and distributed-energy policy under frameworks like the EU EPBD and national net-zero building codes. The harmonic and MPPT results are relevant to grid-code compliance for high-PV-penetration distribution networks.
👥 読者別の含意
🔬研究者:住宅用PVの系統連系設計・MPPT制御・高調波抑制の実装パラメータを参照できる。
🏢実務担当者:戸建住宅のPV容量算定や系統連系機器選定の設計手順として活用できる。
🏛政策担当者:住宅PV普及時の系統連系要件や高調波基準の設計根拠として参考になる。
📄 Abstract(原文)
Decarbonising residential buildings is a combination of energy demand reduction on the demand side and renewable electricity generation on the supply side. In Shanghai, rooftop photovoltaic (PV) generation could be a viable option to reduce household electric power consumption for detached residential buildings, provided PV array sizing, design of power conversion, grid-filtering and control strategy are tailored. In this paper a preliminary electrical design of a grid connected PV power generation system is based on the low carbon residential building to provide the annual electricity balance is developed. Given a winter design demand of 17.8 kWh/day, an effective sunshine duration of 3.8 h/day and a system-loss coefficient of 1.8, the PV capacity is found to be 8.43 kW. A 10.08 kWp array is selected for use, which consists of 24 mono-crystalline silicon modules, and an estimated module area of 48.0m2. The design is also specified by the direct current (DC) bus voltage of 400 V, the frequency of the DC-DC boost converter of 10 kHz, the frequency of the single-phase sinusoidal pulse-width modulation (SPWM) inverter of 20 kHz, and an inductor-capacitor-inductor (LCL) grid filter. A hybrid constant-voltage and perturb-and-observe maximum power point tracking (MPPT) strategy is employed to enhance the PV operating point tracking under the condition of irradiance change. The simulation results reveal that the hybrid MPPT controller is able to track the new MPP following an irradiance drop from 1200 W/m2 to 600 W/m2 at t=0.8 s. Capacitor current feedback active damping for the LCL filter suppresses the resonance peak and the grid current total harmonic distortion is less than the design limit of 5.00% at 2.45%. These results are helpful for electrical feasibility of the proposed grid connected residential PV system.