大規模教育建築物におけるハイブリッド再生可能エネルギーシステムの技術経済的実現可能性と運用排出評価:トルコのケーススタディ

Techno-Economic Feasibility and Operational Emission Assessment of Hybrid Renewable Energy Systems for a Large Educational Building: A Case Study in Türkiye (原題)

Kocabey S, Dursun SÜ

Research Squareプレプリント2026-10-15#再生可能エネルギーOrigin: Global経営インパクト: コスト削減対象セクター: construction
DOI: 10.21203/rs.3.rs-11245532/v1
原典: https://doi.org/10.21203/rs.3.rs-11245532/v1

🤖 gxceed AI 要約

日本語

トルコの大規模教育施設を対象に、系統連系・独立型のハイブリッド再エネシステム(PV・風力・バイオガス)をHOMERで技術経済評価した。系統連系ではGrid/PV/BiomassがNPC約185万ドル・COE0.199ドル/kWh・再エネ比率70%で最小コスト、独立型ではWT/PV/Biomass/BatteryがCOE0.555ドル/kWhで最安だった。運用CO2は系統連系で78〜81%、独立型で99%以上削減されるが、これは運用段階のみの削減である。

English

This study models grid-connected and off-grid hybrid renewable systems (PV, wind, biogas) for a large educational building in Türkiye using HOMER. The least-cost grid-connected option (Grid/PV/Biomass) reaches 70% renewable fraction at $0.199/kWh, while off-grid configurations cut operational CO2 by over 99%. Results highlight trade-offs between renewable penetration, emissions and cost, with wind playing only a supplementary role.

Unofficial AI-generated summary based on the public title and abstract. Not an official translation.

📝 gxceed 編集解説 — Why this matters

日本のGX文脈において

日本のGX文脈では、自治体・公共施設の再エネ調達やPPA検討、地域バイオマス活用の実現可能性評価の参考事例となる。ただしトルコ固有の資源条件・電力価格に依存するため、日本への直接適用には注意が必要。

In the global GX context

Adds a site-specific techno-economic case to the global evidence base on building-level hybrid renewables and operational decarbonization, relevant to corporate RE100/PPA planning and scope 2 reduction strategies. The explicit separation of operational vs. life-cycle emissions is a useful methodological reminder for disclosure under GHG Protocol.

👥 読者別の含意

🔬研究者:HOMERを用いた建物単位HRESの技術経済・運用排出評価の実証例として、再エネ比率とコストのトレードオフ分析に有用。

🏢実務担当者:公共施設や自社ビルでのPV・バイオマス・蓄電池導入検討時のコスト・再エネ比率・排出削減の目安として参照可能。

🏛政策担当者:公共建築物の再エネ化支援策や地域バイオマス活用の政策設計において、系統連系と独立型の費用差の参考になる。

📄 Abstract(原文)

<title>Abstract</title> <p>This study evaluates the techno-economic performance and operational emissions of grid connected and off-grid hybrid renewable energy systems (HRES) for a large educational building in Turkiye. The building’s hourly electricity-demand profile for 2020–2025 and local solar, wind and livestock-manure resources were modeled in HOMER (Hybrid Optimization of Multiple Energy Resources). Photovoltaic (PV), wind-turbine (WT) and biogas-generation alternatives were assessed using net present cost (NPC), cost of energy (COE), renewable fraction and modeled operational emissions. Among the grid connected alternatives, the Grid/PV/Biomass configuration was the least-cost option, with an NPC of approximately $1.85 million, a COE of $0.199/kWh and a renewable fraction of 70%. Adding wind increased the renewable fraction to 72% but raised the COE to $0.263/kWh. Among the off-grid cases, the WT/PV/Biomass/Battery configuration had the lowest COE ($0.555/kWh) and generated 1,006,808 kWh/year, with PV, biogas and wind contributing approximately 48%, 40% and 12%, respectively. The low wind-turbine capacity factor (4.85%) indicates a supplementary role for wind at the site. Relative to the grid-only baseline, modeled operational CO₂ emissions decreased by more than 99% in the off-grid configurations and by approximately 78–81% in the grid-connected cases; these are operational rather than life-cycle savings. A separate analytical grid-only reference shows that the least-cost HRES is not necessarily cheaper than continued grid supply under the fixed 2025 reference purchase price of $0.05/kWh. The results demonstrate a trade-off between renewable penetration, operational emission 2 reduction and system cost, and highlight the importance of site-specific resource quality, biomass logistics and reliability metrics.</p>